System
|
Internal
Plasterboard
|
External
Plasterboard
|
Charfactor
|
FRL*
|
|
OutRWALL™90B
|
1
x 10mm
Standard Core
|
2
x 13mm Wet Area Firestop
as per system TS15
|
N/A
|
90/90/90
from outside only
|
|
OutRWALL™90C
|
2
x 13mm
Firestop
|
1
x 16mm Wet Area Firestop
as per system TS3
|
N/A
|
90/90/90
from both sides
|
|
OutRWALL™90D
|
1
x 16mm
Firestop
|
1
x 16mm Wet Area Firestop
as per system TS3
|
11
|
90/90/90
from outside
60/60/60 from inside
|
• Frame and
footings to be in accordance with AS 1684 - 1999 "Residential
Timber Framed Construction" and AS 2870 - 1996 "Residential Slabs
and Footings - Construction".
• Provide movement joint where timber shrinkage is expected.
• Brick and stump footing options are also available. Contact
Boral Plasterboard for details (see "Sales Offices"
page).
• Ensure that lateral support to top of wall is maintained during
a fire event.
• * Warrington Fire Research Assessment
Nos. WFRA C91580 and WFRA C91585.