Technical Literature

 

Construction Details



System
Internal Plasterboard
External Plasterboard
Charfactor
FRL*
OutRWALL™60
1 x 10mm
Standard Core
1 x 16mm Wet Area Firestop
as per system TS3
11
60/60/60
from outside only
OutRWALL™90
1 x 10mm
Standard Core
2 x 16mm Wet Area Firestop
as per system TS14
N/A
90/90/90
from outside only
OutRWALL™90A
1 x 16mm
Wet Area Firestop
2 x 16mm Wet Area Firestop
as per system TS14
11
90/90/90 from outside
60/60/60 from inside

• Frame and footings to be in accordance with AS 1684 - 1999 "Residential Timber Framed Construction" and AS 2870 - 1996 "Residential Slabs and Footings - Construction".
• Provide movement joint where timber shrinkage is expected.
• Brick footing options are also available. Contact Boral Plasterboard for details (see "Sales Offices" page).
• Ensure that lateral support to top of wall is maintained during a fire event.
* Warrington Fire Research Assessment No. WFRA C91580